brown wooden house near green trees under blue sky during daytime

The Flue Decides: Maywood Chimney Inspection and Repair

Put Your Flue on Camera

Say what burns below the chimney; we reply with the level and price.

Video on Level 2Itemized scopesDefects logged by depth
Camera Stills in Every Report
Defects Logged by Depth
Liners Sized to the Appliance
Written Scope Before Work
Published Inspection Prices
Before and After Footage
Camera Stills in Every Report
Defects Logged by Depth
Liners Sized to the Appliance
Written Scope Before Work
Published Inspection Prices
Before and After Footage
Hayward Chimney Pros, Maywood

Tile, liner, cap: the parts nobody sees from the room.

Each card lists what the job involves on site. Where a price is published, the service page states it; the rest get an itemized scope after a camera look.

01

Chimney Sweep

Creosote glaze and loose soot cleared from tile or steel walls, then a camera confirms the flue is bare before we pack up.

Brush heads matched to round, square or oval flues
Smoke shelf and damper lip scraped clear
Firebox held under vacuum while we brush
Creosote stage noted: dust, flakes or glaze
See the details
02

Chimney Inspection

NFPA 211 inspections read from the flue outward, with tile joints, offsets and the crown recorded on camera.

Clay tile joints read for gaps and lost mortar
Offsets and bends logged by depth from the top
Crown, cap and flashing seen from the roof
Full-height video on the Level 2 visit
See the details
03

Chimney Repair

Cracked tiles, open joints and failed mortar fixed in an order set by what the inspection footage found, top first.

Fix order taken from the camera log
Split or shifted flue tiles reset or replaced
Smoke chamber walls parged smooth
Crown cracks closed so water stops reaching tile
See the details
04

Fireplace Inspection

The room end of the system checked: firebox brick, damper seat, hearth extension and the throat where smoke enters the flue.

Firebrick faces and joints tapped and read
Damper seat and plate checked for warping
Throat and smoke shelf lit and photographed
Hearth extension and trim gaps measured
See the details
05

Fireplace Repair

Spalled firebrick, a cracked rear panel, a warped damper or a gap at the throat repaired so smoke heads up the flue.

Broken firebrick cut out and relaid
Refractory mortar in every firebox joint
Listed rear and side panels for metal boxes
Throat gaps closed where smoke rolls out
See the details
06

Chimney Level 2 Inspection

A camera pulled through every foot of the flue, with attic and roof passages checked and the footage kept on file.

Joint by joint camera log with depths
Attic and roof passages looked at for scorching
Liner fit judged for an insert or new appliance
Marked stills you can forward to a buyer or insurer
See the details
07

Chimney Cap Installation

A cap sized to the tile or liner outlet, with a spark screen and fixings that suit the crown it sits on.

Outlet measured on the tile or liner top
Screen open area checked against draft needs
Single-flue or crown-mount styles
Fixed with screws or clamps, never glue alone
See the details
08

Chimney Flashing Repair

Leaks along the roof joint found by water test, then step and counter metal renewed so the attic stays dry.

Water test run one side at a time
Counter metal set into a cut reglet
Step pieces woven with each roofing course
Attic side checked for stained framing
See the details
09

Chimney Masonry Repair

Spalled brick, sandy joints and loose courses repaired on the outside of the stack, matched in hardness to the old work.

Joints cut back and repointed
Spalled faces replaced with matching brick
Loose top courses relaid
Mortar strength chosen to suit old brick
See the details
10

Chimney Rebuilds

A chimney too cracked or loose to patch taken down and rebuilt, with a new flue sized to whatever it will serve.

Teardown stopped at the first solid course
New tile or stainless liner sized to the appliance
Reinforcing steel where the permit calls for it
Fresh crown, cap and roof flashing
See the details
11

Fireplace Cleaning

Ash, soot and tar residue cleared from the firebox, doors and smoke shelf so the opening looks and draws as it should.

Firebox floor and walls brushed and vacuumed
Tar scraped from the damper seat
Door glass cleaned to suit its type
Grate and andirons cleared of buildup
See the details
12

Gas Fireplace Cleaning

Burner ports, pilot hood and glass cleaned on a gas unit, with the vent run checked for nests, rust and loose joints.

Ports and pilot hood cleared of dust and lint
Media laid back to the manual's diagram
Glass film removed with the right cleaner
Thermopile output read on a meter
See the details
13

Gas Fireplace Repair

Ignition faults, weak flames and shutdowns on gas units traced with a meter, then fixed with the listed replacement part.

Millivolt reading at the thermopile
Flame sensor and igniter cleaned or replaced
Valve and receiver tested in turn
Spill switch checked for vent blockage
See the details
14

Fireplace Remodel

A refaced or rebuilt fireplace planned from the flue up, so the new look sits on a firebox and liner that work.

Flue and firebox checked before design
Clearances to trim and mantel worked out early
Heat-rated setting materials for the face
Liner and insert folded into one scope
See the details
15

Fireplace Inserts

Wood or gas inserts fitted with a stainless liner run to the top, sized by flue area so the draft matches the appliance.

Firebox dimensions checked against the spec sheet
Liner diameter taken from the maker's figures
Liner joined at the collar and capped at the top
Throat damper removed where it blocks the liner
See the details
16

Pellet Stove Repair

A pellet stove that jams, fails to light or shuts itself off, traced part by part, with its exhaust pipe cleared of fly ash.

Igniter resistance and feed motor tested
Vacuum and high-limit switches checked
Exhaust pipe and liner cleared of fly ash
Door and ash pan seals renewed
See the details
17

Wood Stove Repair

Baffles, firebrick, door seals and the connector pipe on a wood stove repaired, with the flue checked for tar above the collar.

Door and glass seals renewed
Warped baffles and cracked brick replaced
Connector pipe joints and pitch checked
Flue collar inspected for tar buildup
See the details
18

Gas Logs

A gas log set placed where the wood fire used to burn, with the flue kept clear for exhaust from a vented burner.

Flue checked before any set goes in
Burner width chosen for the opening
Damper stop so the flue stays open
Gas connection leak tested
See the details
19

Chimney Seismic Retrofit

Unreinforced brick chimneys braced, banded or rebuilt lighter above the roof, after a camera check of the flue inside.

Brick and mortar strength judged first
Flue camera log before any bracing plan
Roof brace tied back to the framing
Metal bands at floor and ceiling lines
See the details
20

Chimney Crown Repair

Cracks across the chimney top sealed or the top recast, so rain stops getting to the flue tile from above.

Crack width and depth gauged on the roof
Flexible sealant for fine cracks
Crumbling tops removed and recast
Expansion room left around the tile
See the details
21

Dryer Vent Cleaning

Lint packed in the dryer duct cleared from end to end, with the run checked for crushed sections and a stuck outside flap.

Full run cleared from machine to hood
Crushed foil or vinyl sections flagged
Outside flap checked for free swing
Screw tips inside joints noted as lint traps
See the details
22

Chimney Liner Installation

Stainless liners chosen by diameter and alloy for the appliance below, run in one length to a sealed top.

Diameter set from the appliance spec
Alloy chosen for wood or gas exhaust
One continuous length, no joints in the flue
Insulating wrap where tile is missing
See the details
23

Chimney Leak Repair

Damp walls, rusty dampers and drips in the firebox followed up the chimney to where the water enters, then stopped there.

Water test from the bottom of the stack up
Camera look for wet or stained tile
Crown, cap and flashing checked from the roof
Fix placed at the entry, not the drip
See the details
24

Chimney Waterproofing

A breathable repellent on repaired chimney brick, so the masonry sheds rain and still dries out between storms.

Brick tested for how fast it takes water
Repairs finished before any coating
Siloxane repellent that lets vapor out
Roof and windows masked during spraying
See the details
25

Chimney Damper Repair

A damper that sticks, rattles or shows daylight repaired at the throat, or replaced with a sealing top damper.

Plate, hinge and handle linkage checked
Rust and tar cleared from the seat
Throat plate swapped where the frame allows
Top-mounted damper with a pull cable
See the details
26

Chimney Chase Cover

Rusted or sagging metal tops on prefab chimneys replaced with a custom stainless top that pitches water away from the pipe.

Old top lifted and the framing checked
Stainless top with a raised center
Folded edges past the enclosure walls
Pipe collar sealed at the exit
See the details
Living room with a white-mantel fireplace and leather recliners

Order of Work

Film the flue, mark the defects, size the fix, film it again.

Flue Work From Maywood

The flue decides what a chimney can safely carry.

Maywood houses hide a lot inside their chimneys. Hayward Chimney Pros films each flue, marks what it finds by depth, and prices the fix line by line.

Clay flue tile cracks quietly. A joint opens, a tile slips half an inch, a corner flakes off, and nothing changes in the room until heat or water finds the gap. Our camera finds it first, and the report puts a depth on every mark.

From there the fix follows the footage: a handful of tiles, a stainless liner sized to the appliance, an insert lined to the top, or a rebuild from the first solid course. You see the evidence before you see a price.

Camera through the flue first

Each defect tagged with its depth

Liner diameter from the maker spec

Stills retaken after the work

The Question Behind Most Calls

Can this chimney take an insert, a stove or another winter of fires?

The footage answers it, and the report keeps the answer on file.

Footage Over Guesswork

Every repair we suggest points to a still from inside the flue. If we cannot show it, we do not sell it.

Sized to the Appliance

Liners, caps and rebuilt flues are matched to what burns below them, from a wood insert to a gas water heater.

Priced Line by Line

Published prices for sweeps, inspections and common jobs; a written scope with each item priced for everything else.

Working From Maywood

Our base is Maywood, and Downey, South El Monte and Los Angeles are our closest regular stops.

Out From Maywood

Old clay flues, shared gas stacks and prefab boxes

Focus cities lead the list. Each of the 140 city pages notes the chimney types common there and what the camera usually turns up.

What the camera sees

House age, fuel and weather shape the flue

A prewar bungalow, a postwar tract house and a newer home with a metal firebox each fail in their own way. The footage tells us which pattern we are looking at.

Shared stacks

Around Maywood, many older houses vent a furnace or water heater beside the fireplace flue, and condensation from gas exhaust eats the top tiles first.

Quake cracks

The 1987 Whittier Narrows and 1994 quakes left hairline splits in many local flues that only show on video, often at the roofline and the first offset.

Oversized flues

Wide fireplace flues are too big for an insert or stove. A stainless liner sized to the outlet brings the draft back and keeps tar off the tile.

Flue Questions

Liners, footage, levels and prices

What owners ask before they let a camera into the chimney. Anything else goes through the contact page.

A lit, wide-angle view of the walls as the head travels up. On clay tile we look at each joint for missing mortar, offsets where one tile has slipped against the next, vertical splits and tile faces that have flaked away. On a steel liner we look for dents, separated sections and heavy glaze. Each defect is logged by its depth from the top, so the report reads like a map of your Maywood chimney.
Clay tile works while it is whole and sized to the appliance. Once tiles split or joints open, heat and exhaust can reach the brick and the framing beside it. A new insert or gas appliance also wants a smaller flue than an open fireplace, and a tile flue sized for a wide opening can be too big for it to draft well. A stainless liner fixes both problems at once.
From the appliance, not the chimney. The maker lists an outlet diameter and sometimes a minimum height. We match the liner to that figure, check that the clay or brick around it leaves room to lower it, and choose an insulated or bare liner depending on the clearances the camera found. Oversizing is as much of a problem as undersizing, because slow, cool exhaust leaves tar.
$52 for a Level 1, which covers what can be seen from the firebox, the roof and any open access. $370 for a Level 2, which adds the camera run through the full flue and the attic and roof passages. If a Level 1 shows something only the camera can settle, the report recommends the step up and says why.
Sometimes. If the damage sits in one or two tiles near the top and the rest of the flue is clean on camera, those tiles can be reached and replaced. When cracks run at several depths, or the tile is too small or too big for the appliance, a stainless liner is usually the cheaper and more reliable path. The footage makes that decision clear; it is not a sales call.
When the brick itself has stopped holding together: courses that move under a hand, a visible lean, broken tile at several depths, or a crown and top section that crumble when touched. Rebuilds go only as far down as the damage, and the new section gets a flue sized for the appliance it will serve. Your written scope names the stopping point.
Yes. Gas exhaust is full of water vapor, and in an oversized or unlined masonry flue it condenses, soaking the tile and mortar from inside. On camera that looks like white crust and crumbling joints near the top. A gas appliance in a masonry chimney often needs its own correctly sized liner, and a shared flue needs a careful look at both appliances.
Yes. Order a Level 2, name your agent as the contact for access, and we send the marked stills and written summary to you and anyone else you list. You can see the inside of the flue from wherever you are, which is the point of the camera report.
It records what we found, where and what we think caused it, with dated stills from inside the flue. That is the kind of evidence adjusters ask for after a chimney fire, a quake or storm damage. Whether a claim is paid is up to the insurer; we describe the damage, not the policy.
Sweeps start from $400. Inspections are $52 for Level 1 and $370 for Level 2. Caps are quoted after we measure, leak repair $530 to $3,200, a cricket $425 to $960 or $640 to $1,600 with new flashing, a gas insert $2,650 to $5,300 and a direct-vent gas fireplace $4,250 to $8,500. Liners, rebuilds and other work get a written scope after we see the chimney.
We work from Maywood and cover Downey, South El Monte and Los Angeles closely, with the rest of the county and neighboring areas on the areas page. Use the contact page with the address and a line on what the chimney serves.
Camera Visit

Find out what your Maywood flue can carry

Planning an insert, buying a house or chasing a leak? A Level 2 shows the full flue on video, and the report marks each defect with its depth and what it means for the next fire.

Use the Contact Page

Form replies 7:00 AM to 7:00 PM, all week

Tell us about the chimney

The reply names a level and its price.

By sending, you agree Hayward Chimney Pros may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Request to Report

From your note to footage of the finished flue

A single sweep and a full liner job move through the same five stages.

01

Tell Us What It Serves

Use the contact form with the address and what the chimney runs: an open fire, an insert, a stove or a gas appliance. Mention anything you have noticed, such as smoke in the room, a smell after rain or a stain near the stack.

02

We Pick the Level

From that note we suggest a Level 1 or a Level 2 and confirm the price on the call: $52 or $370. If you are planning an insert, a sale or a repair after damage, the Level 2 is the one that answers the question.

03

Camera Through the Flue

On site we cover the hearth, check the firebox and damper, and run the camera from the throat to the top. On a Level 2 we also look in the attic and on the roof where the chimney passes through.

04

Marked Stills and a Scope

You receive stills marked with depth and a short note for each defect, plus a written scope for any repair, liner or rebuild, with each line priced. Nothing starts until you approve it.

05

Work, Then Film Again

Once the repair or liner is in, the camera goes back down so you can compare the same depths before and after. The finished stills join your file for the next sale or claim.

Request a Visit

Form replies go out 7:00 AM to 7:00 PM, Monday to Sunday.

Request a Visit